Miller Grip™ Anchorage Connector

FOR USE IN CONCRETE APPLICATIONS
A safe anchor point is established when the Miller Grip™ Anchor is inserted into a properly-sized, cured concrete hole. Designed for use in cured concrete with a compression strength of at least 3,000 psi (20.7 MPa) , it can be used for vertical or overhead/ceiling surface applications.

Features

Reusable
The Miller Grip™ anchor can be removed and simply re-installed in a new location.

Mandatory Safety
A safe anchor point is established when the Miller Grip anchor is inserted into a properly-sized, cured concrete hole.

More Less

Features

  • Designed for vertical or overhead/ceiling surface applications
  • Can be used with SkyGrip Horizontal Lifeline components; 400 lbs. (181.4 kg) capacity (SKU 497/)
  • Multi-use Grips can be used for anchoring scaffolding, material handling and removal of concrete debris after demolition
  • Constructed of stainless steel, aluminum and other non-corrosive materials for a longer service life
  • Designed for use in cured concrete with a compression strength of at least 3,000 psi (20.7 MPa)
  • Color-coded to differentiate fall protection use per OSHA regulations

Literature and Documents

SKU Hole Diameter Description
496/ 3/4-in. (19 mm) 5,000-lb. (2,268 kg) ultimate strength; for single user connection; 400-lbs. (181 kg) maximum capacity; color-coded green
497/ 1-in. (25 mm) 10,000-lb. (4,536 kg) ultimate strength; for single user connection; 400-lbs. (181 kg) maximum capacity; color-coded green
498/ 3/4-in. (19 mm) 1,000-lb. (454 kg) max safe working load for multi-use connection (NOT for fall protection use)
499/ 1-in. (25 mm) 2,000-lb. (907 kg) max safe working load for multi-use connection (NOT for fall protection use)