Miller Fusion Roof Anchor Post

Are you meeting the New OSHA Residential Construction Regulation?Miller Fusion Roof Anchor Post

Permanent or Temporary Solution for Roof Safety

The new versatile, single-point Miller Fusion Roof Anchor Post adapts to a wide range of roof designs with its innovative base plate engineered for temporary or permanent installation to the roof surface.

When properly installed, a dependable fall protection connection is established. Should a fall occur, forces are reduced with its energy-absorbing design to maintain a secure connection to the structure.

The easy-to-install Miller Fusion Roof Anchor Post is designed for quick set-up and does not require roof penetration to sub-surface rafters or trusses.

  • Versatile single-point anchor adapts to a wide range of roof designs - With a variety of models available, the Miller Fusion Roof Anchor Post can accommodate most industrial roof designs including standing seam, membrane, built-up, metal sheathing, concrete and wood.
  • Attaches to the surface of existing roof structures - Quick, easy installation reduces cost requiring minimal labor and eliminating the need for roof penetration and repair.
  • Significantly reduces the fall forces on the roof structure - In the event of a fall, the top of the Miller Fusion Roof Anchor Post reorients with the force in a direct line and activates the patent-pending energy absorber.
  • Durable design that withstands the changing outdoor environment - Internal components are constructed of stainless steel. The steel post and base are plated with zinc followed by a premium powder coating for two layers of protection.
  • Models for steel decking, concrete and wood can be used on other non-roof structures.

360° Protection

Miller Fusion Roof Anchor Post

In the event of a fall, the Miller Fusion Roof Anchor Post orients in the direction of the force, the built-in, energy-absorbing component activates and the base remains securely attached to the roof surface.

Applications

  • Roof inspection and maintenance
  • Air conditioning, ventilation fan and solar panel maintenance
  • Skylight cleaning
  • Debris removal from gutters
  • Installation and maintenance of satellite dishes and other communication systems

Miller Fusion Roof Anchor Post Application

Miller Fusion Roof Anchor Post adapts to a variety of roof structures

Standing Seam Design - SKU X10001
SKU X10001
Standing Seam Design
  • Aluminum clamping mechanism is designed to pre-install to the base plate and is self centering for easy installation.
  • The clamping bolts are tightened from above the plate for easy fastening and inspection.
  • Can be used for permanent and temporary installations.
  • Three models are available to accommodate standing seam spacing up to 24-in. (610 mm).
Metal Sheathing Design - SKU X10011
SKU X10011
Metal Sheathing Design
  • Designed to attach to metal sheathing with a minimum 24 gauge (0.024-in. [.61 mm]) thickness.
  • Hardware kit includes sealing materials to prevent water damage to roof.
Membrane/Built-up Design - SKU X10030/X10031
SKU X10030/X10031
Membrane/Built-up Design
  • Easy-to-install toggle kit fastens through membrane, insulation and into metal sheathing, wood sheathing or concrete.
  • Models available for built-up roof thicknesses accommodate up to 10.5-in. (267 mm).
Wood Design - SKU X10040
SKU X10040
Wood Design
  • Includes lag screw kit.
  • Installs into plywood with minimum thickness of 5/8-in. (15.9 mm) CDX.
  • Designed for temporary installation only.
Concrete Decking Design - SKU X10050
SKU X10050
Concrete Decking Design
  • Includes concrete expansion anchor kit.
  • Installs into concrete decking with minimum thickness of 6.5-in. (165 mm) and minimum concrete compressive strength of 3000 PSI (20.7 MPa).
Multi-Purpose Metal Sheathing, Wood and Concrete Design - SKU X10020
SKU X10020
Multi-Purpose Metal Sheathing, Wood and Concrete Design
  • This multi-purpose post uses the same base as models X10011, X10040 and X10050.
  • Miller specified hardware must be purchased for this base. (This model does not include hardware.)

 

SKUDescriptionDesigned to Accommodate
STANDING SEAM ROOFING – Includes post with base and standing seam clamping assembly kit
X10000 Small base Standing seam spacing from 11.75-in. (298 mm) to 17-in. (432 mm)
X10001 Large base Standing seam spacing from 11.75-in. (298 mm) to 21.25-in. (540 mm)
X10002 Large base & extension bars Standing seam spacing from 11.75-in. (298 mm) to 24-in. (610 mm)
METAL SHEATHING ROOFING – Includes post with base and rivet kit with sealing washers and mastic tape
X10010 Small base Metal sheathing w/minimum thickness of 24 gauge (0.024-in. [0.61 mm])
X10011 Large base Metal sheathing w/minimum thickness of 24 gauge (0.024-in. [0.61 mm]). Trapezoidal spacing of 8-in. (203 mm) to 20-in. (508 mm) in one-inch (25.4 mm) increments.
MEMBRANE/BUILT-UP ROOFING – Includes post with base and toggle bolt kit
X10030 Up to 5.5-in. (140 mm) thickness Fastens through membrane, insulation & into metal sheathing, wood sheathing or concrete with a combined thickness of up to 5.5-in. (140 mm)
X10031 > 5.5-in. (140 mm) & up to 10.5-in. (267 mm) thickness Fastens through membrane, insulation & into metal sheathing, wood sheathing or concrete with a combined thickness of > 5.5-in. (140 mm) up to 10.5-in. (267 mm)
WOOD SHEATHING (temporary installations only) – Includes post with base and lag screw kit
X10040 Wood sheathing Plywood with minimum thickness of 5/8-in. (15.9 mm) CDX
CONCRETE ROOFING – Includes post with base and concrete expansion bolt anchor kit
X10050 Concrete Concrete decking with minimum thickness of 6.5-in. (165 mm) & minimum concrete compressive strength of 3000 PSI (20.7 MPa)
MULTI-PURPOSE METAL SHEATHING, WOOD AND CONCRETE ROOFING (no hardware included) – Includes post with base. Hardware selection is based on the application. See instruction manual for hardware specifications.
X10020 Metal sheathing, wood or concrete
  • Metal sheathing w/minimum thickness of 24 gauge (0.024 in. [0.61 mm])
  • Trapezoidal spacing of 8-in. (203 mm) to 20-in. (508 mm) in one-inch (25.4 mm) increments.
  • Plywood with minimum thickness of 5/8-in. (15.9 mm) CDX
  • Concrete decking with minimum thickness of 6.5-in. (165 mm) & minimum concrete compressive strength of 3000 PSI (20.7 MPa)
Meets or exceeds all applicable industry standards including OSHA, ANSI A10.32 and Z359.1-2007.

Interactive Catalog Now Available!

Easily view the digital version of our "Gravity Kills, Defy It!" 114-page product catalog.

Click Here to View Catalog

Ask the Expert...Ask Miller.
News 4 You
Fall Clearance Calculator
Honeywell Road Show
safety-institute-button.jpg
CSA Z259.12-11 Fall Protection Standard
Home arrow Fall Protection Products arrow Personal Fall Protection Products arrow Roofing Products arrow Fusion Roof Anchor Post
Miller Fall Protection Banner
Technical Service 800/873-5242 +1 814/432-2118
Loading
Region: North America
Generated in 0.240 Seconds